Home / Projects / 3-Building Complex Energy Model

Coordinated 3-Building Complex (Basement + 5 Upper Levels)

When modelling for energy performance, clean, accurate geometry isn't a nice-to-have — it is the entire foundation of your audit. A single coordinated digital twin built from day one to feed directly into thermal evaluations, daylighting, and EPC assessments.

Storeys & Scope 7 Levels (Basement, Ground, 1st–5th)
Total Elements 2,682 Parametric Elements
Wall Count & Volume 1,364 Walls | 6,595.83 m³
Defined Thermal Zones 232 Spatially Defined Rooms
Coordinated 3-Building Complex BIM Model — Architectural Elevation & Fenestration
Front perspective of the coordinated 3-building residential complex, capturing fenestration modulation, continuous thermal envelope, and floor setbacks.

Building Overview & Energy Foundations

At Ribhus, we delivered this coordinated BIM model covering a complex of three distinct buildings spanning a basement through five upper levels (7 storeys total). Built from day one to be the exact data source energy consultants need for audits, thermal evaluations, and EPC assessments.

2,682 Total Geometric Elements Extracted
1,364 Walls with Explicit U-Values & Volumes
602 Windows (1,114.73 m² Glazing Area)
232 Spatially Defined Thermal Room Zones

Floor-by-Floor Wall Count & Volume Breakdown

That taper from 351 walls on the 1st floor down to just 38 on the 5th isn't noise — it's the building's real architectural setback, extracted straight from the mesh geometry. For an energy auditor, that means exact envelope surfaces instead of a guess:

  • Basement: 92 walls | 509.70 m³
  • Ground Floor: 292 walls | 2,193.28 m³
  • 1st Floor: 351 walls | 1,572.56 m³
  • 2nd Floor: 324 walls | 1,433.80 m³
  • 3rd Floor: 187 walls | 675.18 m³
  • 4th Floor: 80 walls | 129.90 m³
  • 5th Floor: 38 walls | 81.41 m³
  • Total Envelope Volume: 1,364 walls | 6,595.83 m³

Windows, Doors & Thermal Fenestration

Fenestration is critical for solar gains and daylight calculation:

  • Windows: 602 individual window assemblies totaling 1,114.73 m² of glazing area — ready instantly for daylighting and thermal envelope calculations.
  • Doors: 412 doors, with heights clustered around 2.135 m and widths ranging from 0.75 m up to 1.80 m double entrance assemblies.
  • Zone-by-Zone Attribution: Every single opening is dimensioned and assigned to its correct floor and thermal zone — no averaging, no assumptions.

232 Spatially Defined Rooms & Zones

Rooms are classified with verified net floor area, perimeter boundaries, and volume spaces:

Room: 47 Corridor: 29 Bathroom: 24 Bedroom: 17 Children's Room: 14 Storage: 13 Living / Dining: 10

This is what an energy-ready digital twin actually looks like: a single coordinated model across all three buildings, capturing shared shading and solar exposure between them, acting as the single source of truth for energy consultants, auditors, and sustainability engineers.

Why Consultancies Partner with Ribhus

Most BIM outsourcing gets you geometry — walls and rooms that look right on screen but still need re-measuring before an audit can use them. What we deliver is fundamentally different: models built specifically to feed simulation and compliance tools directly, with every wall, opening, and room already zoned, dimensioned, and volume-calculated.

For teams running SAP, PHPP, dynamic thermal simulation, or in-house compliance pipelines, we hand over the underlying IFC, XML, or PLN file itself — so your engineers plug it straight into your existing workflow instead of rebuilding from a flat drawing set. That means less time on data reconstruction and more time on the actual analysis your clients are paying for.

Civil Engineering Verification Protocol

In this 3-building complex, zero volume approximations were permitted. Every floor slab thickness, cantilevered setback, and window frame reveal was matched to the source plans to provide an audit-defensible IFC dataset.

Verified by Ribhus Engineering QA · DTU Civil Standards

Ready for Real Audit-Ready BIM Models?

Send us your drawings. We deliver clean, coordinate-accurate models ready for thermal calculations in 24–48 hours.

Start Free Pilot Project